Skip Navigation
Skip to contents

ACC : Acute and Critical Care

OPEN ACCESS
SEARCH
Search

Author index

Page Path
HOME > Issue > Author index
Search
Jai Woog Ko 2 Articles
A Simulation Study for Quality of Chest Compression Provided by Health Personnel
Jun Mo Yeo, Min Hong Choa, Sang Won Chung, In Byung Kim, Ji Hoon Kang, Kyung Wuk Kim, Jai Woog Ko
Korean J Crit Care Med. 2011;26(2):64-68.
DOI: https://doi.org/10.4266/kjccm.2011.26.2.64
  • 2,334 View
  • 26 Download
  • 2 Crossref
AbstractAbstract PDF
BACKGROUND
Effective chest compression may improve the return of spontaneous circulation and neurologic outcome in arrest victims. For fear of rescuer's fatigue, guidelines for cardiopulmonary resuscitation (CPR) recommended that chest compression (CC) should be switched every 2 minutes, but there is little evidence. We investigated whether health personnel could provide consistent quality of CC for 2 minutes.
METHODS
We recruited prospectively health personnel working on one university hospital. On the day assigned randomly, CPR performance data was collected with use of CPR recording technology. Quality of CPR was calculated every 30 seconds interval. To identify the quality decay, we used repeated measure analysis of variance with SPSS 17.0 for analysis.
RESULTS
We analyzed 8,485 CCs performed by 41 subjects. Total number of CC decayed between 90 to 120 seconds (51.6 +/- 3.3 to 50.8 +/- 3.5, p = 0.020) within recommended range. The ratio of correct depth CC decayed between 90 to 120 seconds, falling from 83.4 +/- 24.9% to 68.3 +/- 38.4% (p = 0.002). The ratio of low depth CC increased significantly over time (10.2 +/- 20.7% to 31.3 +/- 38.5%, p < 0.001).
CONCLUSIONS
Health personnel may provide adequate number of CC for 2 minutes. But, the number of correct depth CC may decay between 90 to 120 seconds. Also the number of low depth CC may increase over time.

Citations

Citations to this article as recorded by  
  • Comparisons of the qualities of chest compression according to various positions of rescuer to patient at the in-hospital cardiopulmonary resuscitation model
    Geon-Nam Kim, Seong-Woo Choi, Jin-Yeong Jang, So-Yeon Ryu
    The Korean Journal of Emergency Medical Services.2014; 18(1): 7.     CrossRef
  • Comparison on the Quality and fatigue of hands-Only CPR According to the Presence or Absence of Verbal counting by Some Middle-aged Women
    Geon-Nam Kim, Sung-Soo Choi, Seong-Woo Choi
    Journal of the Korea Academia-Industrial cooperation Society.2013; 14(3): 1320.     CrossRef
Variations in Pulse Oximetry Plethysmographic Waveform Amplitude and Hemodynamic Assessment Induced by Passive Leg Raising in Spontaneously Breathing Adult Volunteers
Jai Woog Ko, Sang Weon Chung, Yo Seob Park, Kyo Joon Lee, Dong Seok Moon, In Byung Kim
Korean J Crit Care Med. 2008;23(1):6-12.
DOI: https://doi.org/10.4266/kjccm.2008.23.1.6
  • 2,813 View
  • 32 Download
AbstractAbstract PDF
BACKGROUND
In hemodynamically unstable patients with spontaneous breathing activity, predicting volume responsivenss is a difficult challenge. Our objective was to test whether the respiratory changes in pulse oxymetry plethysmographic waveform amplitude (POP) and in stroke volume (deltaSV) could predict fluid responsiveness to passive leg raising (PLR) in normal volunteers.
METHODS
We investigated 25 normal volunteers. We assessed hemodynamic status (HR, SBP, MAP, CI and SVI) and calculated the respiratory variation in pulse oximetry plethysmographic waveform amplitude at supine and after PLR. We attached a pulse oximeter of 25 spontaneously breathing volunteers as several time points: after 1 min and 5 min in supine position and during PLR at 60degrees. Heart rate, non-invasive blood pressures (mean arterial pressure, systolic blood pressure), maximal POP (POPmax), minimal POP (POPmin) and deltaPOP defined as (POPmax-POPmin)/[(POPmax+POPmin)/2] were recorded using monitor.
RESULTS
Comparing to supine and PLR, systolic blood pressure and mean arterial pressure were not different, but the change in cardiac index, stroke volume and respiratory variation in POP were significant different. In response group (> or =10% in deltaCI), the change in cardiac index, stroke volume and respiratory variation in POP were significant greater.
CONCLUSION
PLR induces a significant decrement of variation in POP amplitude among spontaneouely breathing volunteers. We suppose that the changes in stroke volume and the respiratory variation in pulse oximetry plethysmographic waveform amplitude induced by PLR predict fluid responsiveness in spontaneous breathing patients.

ACC : Acute and Critical Care